Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ES230 Mini Economy VFD
ES230 is a newly designed smart variable frequency drive, featuring compact structure, easy-to-use, excellent performance and various functions. It can be widely used in woodworking, textile, food, printing and packaging, plastics, machine tools, transportation equipment industries etc.
AC 1PH 220V~240V 0.4~5.5kW
AC 3PH 220V~240V 0.4~5.5kW
AC 3PH 380V~415V 0.75~11kW
Application:
Woodworking, textile, food, printing and packaging, plastics, machine tools, cable, transportation equipment industries etc.
1. Next-generation motor control platform
Capable of driving asynchronous and permanent magnet synchronous motors, supporting FVC, SVC and V/F control modes
2. Refined design with significant size reduction
With next-generation power device technology, it features high junction temperature, high power density and smaller dimension, reducing size up to 30% and installation
area of 70%.
3. Optimized vector control technology, bringing breakthrough in motor control performance
SVC speed control ratio is increased to 1:1000; SVC replaces FVC when the output torque is greater than 10%; SVC winding and unwinding torque accuracy is ≤ 5%.
4. Fast current limiting
When exceeding the limit, the current can be quickly limited to within the limit, avoiding frequent overcurrent alarms caused by sudden loads or disturbances.
5. Unique speed tracking
Requiring no special hardware detection circuit, it can track the motor speed and direction quickly without any impact. It is especially suitable for fans, pumps and other
equipment that requires speed tracking.
6. Overexcitation function
Rapid braking effect can be achieved without adding external brake resistors and other accessories;
It can suppress the rise of bus voltage during deceleration to avoid frequent over-voltage fault alarms. Additionally, it can brake quickly, meeting the requirement of quick
stopping at shutdown.
7. Stable, reliable and long product life
Independent airduct design and standard coated PCB prevent dust and oil from entering the VFD and fully protect the electronic components on the PCB, thus ensuring longer service life and reliability.
8. Powerful upper computer monitoring software
Extensive background monitoring functions which facilitate on-site data collection and debugging; online oscilloscope function; batch uploading and downloading
parameters; displaying Group U0 parameters in real time; and monitoring and diagnosis functions.
Good features based on our professional production:
Technical Item | Specification | |
Basic function |
Output frequency | Vector control: 0~500Hz V/f control: 0~3200Hz |
Control mode | V/f control Sensorless vector control (SVC) |
|
Carrier frequency | 0.8kHz~12kHz, automatically adjusted based on the load characteristics | |
Input frequency resolution | Digital setting: 0.01Hz Analog setting: maximum frequency * 0.025% |
|
Starting torque | G type: 0.5Hz/150% P type: 0.5Hz/100% |
|
Speed adjustment range |
1:100 (SVC) | |
Speed stability accuracy | ±0.5% (SVC) | |
Overload capacity |
G type: 150% 60s; 180% 3s P type: 120% 60s; 150% 3s |
|
Torque boost | Automatic torque boost; manual torque boost 0.1%~30.0% | |
V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) |
|
V/f separation | 2 modes: complete separation, half separation | |
Acceleration/ deceleration mode |
Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~6500.0s | |
DC braking | DC braking frequency: 0.00Hz~maximum frequency Braking time: 0.0s~36.0s Braking action current value: 0.0%~100.0% |
|
Jog control | Jog frequency range: 0.00Hz~50.00Hz Jog acceleration/deceleration time: 0.0s~6500.0s |
|
Simple PLC & multi-step speed operation | It can realize up to 16 steps speed via the built-in PLC function or control terminal. | |
Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
Automatic voltage Regulation (AVR) |
Automatically maintain a constant output voltage when grid voltage changes | |
Common DC bus | Common DC bus for several inverters, energy balanced automatically | |
Overvoltage & overcurrent stall control | Automatically limit the current and voltage during the operation, prevent frequent overcurrent and overvoltage trip | |
Rapid current limit | Minimizing overcurrent fault, protect the normal operation of inverter | |
Torque limit & control | "Excavator" characteristics, automatically limit the torque during the operation, prevent frequent overcurrent trip; torque control can be achieved on close-loop vector control mode. |
|
Fault protection function | Overcurrent, overvoltage, under-voltage, overheating, default phase, overload, short-circuit, etc., can record the detailed running status during failure & has fault automatic reset function | |
Individualized function |
Non-stop when instantaneous power off |
The load feedback energy compensates the voltage reduction when instantaneous power off, so that the AC drive can continue to run for a short time. |
Virtual IO | Five groups of virtual DI/DO can realize simple logic control. | |
Timing control | Time range: 0.0min~6500.0min | |
Multi-motor switching | 2 groups of motor parameters, arbitrary switching between 2 motors | |
Communication protocol |
Standard MODBUS (RS-485) | |
Operation | Running command source | Keypad control Terminal control Serial communication control |
Frequency source | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
Auxiliary frequency source |
There are ten auxiliary frequency sources. It can implement fine tuning and frequency synthesis. |
|
Input terminal | 6 digital input (DI1~DI6), DI6 supports max. 100 kHz high-speed pulse input. 2 analog input: AI1: 0~10V AI2: 0~10V or 4~20mA |
|
Output terminal | 1 output (FM), optional for open collector output or high-speed pulse output (0~100kHz) 1 relay output 1 analog output: AO: 0~10V or 0/4~20mA |
We use famous TI or Infineon DSP for control board, here is wiring diagram:
We have 1 phase 220V, 3 phase 220V and 3 phase 380V models, which model is suitable for your application?
Model | Motor | Rated Input Current (A) |
Rated output Current (A) |
|
kW | HP | |||
1AC 220~240V±15% | ||||
ES230-2S0.4G | 0.4 | 0.5 | 5.4 | 2.3 |
ES230-2S0.75G | 0.75 | 1 | 8.2 | 4.0 |
ES230-2S1.5G | 1.5 | 2 | 14 | 7.0 |
ES230-2S2.2G | 2.2 | 3 | 20 | 9.6 |
ES230-2S3.7G | 3.7 | 5 | 35 | 17 |
ES230-2S5.5G | 5.5 | 7.5 | 50 | 25 |
3AC 380~415V±15% | ||||
ES230-4T0.75G | 0.75 | 1 | 2.4 | 2.1 |
ES230-4T1.5G | 1.5 | 2 | 4.6 | 3.8 |
ES230-4T2.2G | 2.2 | 3 | 6.3 | 5.1 |
ES230-4T3.7G | 4 | 5 | 11.4 | 9 |
ES230-4T5.5G | 5.5 | 7.5 | 16.7 | 13 |
ES230-4T7.5G | 7.5 | 10 | 21.9 | 17 |
ES230-4T11G | 11 | 15 | 32.2 | 25 |
We focus on manufacturing vfd, solar pump inverter and hydraulic serve drive from 2013. See photos know more about our factory:
Besides manufacture, we also pay more attention to company team building. We held many activities as photos showing:
Q1: Can I have a sample order?
A1: Yes, we welcome sample order to test and verify the quality and performance. Mixed model samples are acceptable too.
Q2: Do you have any MOQ limit?
A2: NO MOQ. Please just send us inquiry.
Q3: What is the lead time?
A3: We have some stock for common models. Common model samples take 1-3 days; bulk orders take 3-10 working days. Uncommon models take 20-30 working days and depends on the actual situation of the production line.
Q4: Do you offer warranty for the products?
A4: Yes, we provide 18 months warranty for the failure or damage under normal use conditions. If the equipment has been used for over 18 months, reasonable repair expenses will be charged.